Sample Gas Probes

 

GAS 222.15

  • Heated 180° C
  • 115-230 Volt
  • Basc unit
  • Selfregulating heater element
  • Low temperature alarm at
    140° C
  • Insulation jacket
  • Incl. flange gasket and screws

      Datasheet
      Instruction manual
 

GAS 222.17

  • Heated 180° C
  • 115-230 Volt
  • Basc unit
  • Weather shield
  • Selfregulating heater element
  • Low temperature alarm at
    140° C
  • Insulation jacket
  • Incl. flange gasket and screws

    Datasheet
    Instruction manual
 

    GAS 222.20

  • Heated, temperature adjustable up to 200° C
  • 115V or 230V
  • Basic unit
  • Weather shield
  • Cartridge heaters are regulated by an electronic controller
  • High and low temp. alarm output
  • Insulation jacked
  • Incl. flange gasket and screws

    Datasheet
    Instruction manual
 

GAS 222.21

  • Heated, temperature adjustable up to 200° C
  • 115V or 230V
  • Basic unit for in-situ and downstream filter
  • Weather shield
  • Selfregulating heater element
  • High and low temp. alarm output
  • Insulation jacked
  • Incl. flange gasket and screws

    Datasheet
    Instruction manual
 

GAS 222.31

  • Heated, temperature adjustable up to 200° C
  • 115V or 230V
  • Basic unit with manual shut off valve
  • Blowback connection
  • Weather shield
  • Selfregulating heater element
  • High and low temp. alarm output
  • Insulation jacked
  • Incl. flange gasket and screws

    Datasheet
    Instruction manual
 

GAS 222.35

  • Heated, temperature adjustable up to 200° C
  • 115V or 230V
  • Basic unit with blowback connection
  • Weather shield
  • Selfregulating heater element
  • High and low temp. alarm output
  • Insulation jacked
  • Incl. flange gasket and screws

    Datasheet
    Instruction manual
 

GAS 222.10

 

GAS 222.11

  • Unheated
  • Basic unit with manual shut off valve
  • For in-situ and downstream filter
  • With blowback connection
  • Incl. flange gasket and screws

    Datasheet
    Instruction manual
 

GAS 222.20DH

 

GAS 222.30

  • Unheated
  • Basic unit with manual shut off valve
  • With blowback connection
  • Without integrated downstream filter
  • Incl. flange gasket and screws

    Datasheet
    Instruction manual
 

GAS 222.35U

 

ECO-01

 

APO

 

GAS 222.20 ATEX

  • Heated up to 80° C at
    Ta = 25° C
  • 115V or 230V
  • Basic unit
  • Ex II 2G/D EEx ce IIC T4
    130° C
  • Weather shield
  • Selfregulated heater element
  • Explosion proofed terminal box
  • Insulation jacket
  • Incl. flange gasket and screws

    Datasheet
    Instruction manual
 

GAS 222.21 ATEX

  • Heated up to 90° C at
    Ta = 25° C
  • 115V or 230V
  • Basic unit with manual shut off valve
  • Ex II 2G/D EEx ce IIC T4
    130° C
  • For in-situ and downstream filter
  • Weather shield
  • Selfregulating heater element
  • Blowback connection
  • Explosion proofed terminal box
  • Insulation jacket
  • Incl. flange gasket and screws

    Datasheet
    Instruction manual
 

GAS 222.31 ATEX

  • Heated up to 90° C
  • 115V or 230V
  • Basic unit with manual shut off valve
  • Ex II 2G/D EEx ce IIC T4
    130° C
  • Weather shield
  • Selfregulating heater element
  • Blowback connection
  • Explosion proofed terminal box
  • Insulation jacket
  • Incl. flange gasket and screws

    Datasheet
    Instruction manual

GAS 222.35 ATEX

  • Heated up to 80° C
  • 115V or 230V
  • Basic unit with blowback connection
  • Ex II 2G/D EEx ce IIC T4
    130° C
  • Weather shield
  • Selfregulating heater element
  • Explosion proofed terminal box
  • Insulation jacket
  • Incl. flange gasket and screws

    Datasheet
    Instruction manual

GAS 222.20 ATEX2

  • Heated up to 70° C at
    Ta = -20° C
  • 115V or 230V
  • Ex II 3G EEx nA L IIC T4 ; 3G c IIC T4
  • Basic unit
  • Weather shield
  • Selfregulating heater element
  • High and low temp. alarm output
  • Insulation jacket
  • Incl. flange gasket and screws

    Datasheet
    Instruction manual
 

GAS 222.21 ATEX2

  • Heated up to 120° C / T3 up to
    70° C / T4
  • 115-230 Volt
  • Ex II 3G EEx nA L IIC T3 ; 3G
    c IIC T3
  • Basic unit with manual shut off valve
  • For in-situ and downstream
  • Weather shield
  • Selfregulated heater element
  • Blowback connection
  • Insulation jacket
  • IIncl. flange gasket and screws

    Datasheet
    Instruction manual

GAS 222.31 ATEX2

  • Heated up to 120° C/T3, 70°C / T4
  • 115-230 Volt
  • Basic unit with manual shut off valve
  • Ex II 3G EEx nA L IIC T3 ; 3G c IIC T3
  • Weather shield
  • Selfregulating heater element
  • Blowback connection
  • Insulation jacket
  • Incl. flange gasket and screws

    Datasheet
    Instruction manual

GAS 222.35 ATEX2

  • Heated up to  70°/120° C
  • 115-230 Volt
  • Basic unit with blowback connection
  • Ex II 3G EEx nA L IIC T3 ; 3G c IIC T3
  • Weather shield
  • Selfregulating heater element
  • Insulation jacket
  • Incl. flange gasket and screws

    Datasheet
    Instruction manual